The technically advanced BRAVO Home UPS operates on mains and supplies power while charging the battery when Mains supply is available. In case of a power outage, Bravo transfers the entire load to its optimally charged battery and supplies high quality AC power. Apart from the highest quality components and engineering, what makes Bravo special is the inbuilt stabilizer and charger. With Bravo there is no need to purchase an additional voltage stabilizer, or a charger for charge recovery in case the battery is exhausted. This is why it is becoming the most popular sine-wave UPS in the market.
रु. 39999.00
VAT bill available EMI consultation
In stock Free delivery Genuine warranty
100% Genuine
Factory-sealed, authentic products
Free Delivery
Across Nepal on all orders
Expert Install
Certified technician setup
After-sales
Dedicated support team
Specifications
| Length (mm) | 340 |
| Width (mm) | 230 |
| Height (mm) | 260 |
| Model Name | 3200VA |
| Output Wattage | 2560 Watt |
| Mains AC low-high cut UPS mode | 175VAC-265VAC ± 10V |
| Mains AC low-high recovery cut UPS mode | 185VAC- 255 VAC ± 10VAC |
| Mains AC low-hgh cut WUPS mode | 90VAC - 295VAC ± 10VAC |
| Mains AC low-high recovery cut WUPS mode | 110VAC - 285VAC ± 10VAC |
| Input Frequency Range | 48Hz to 52Hz |
| DC Input Voltage | 24V |
| Battery deep discharge recovery | Yes (Independent Charger to Recover Deep Discharge Battery) |
| Charging Current 100 Ah-135Ah Settings | 12A/15A ± 2A |
| Output Voltage/Frequency | 220VAC + 5% -10% (until battery low alarm) |
| Output Frequency | 50Hz ± 0.2Hz |
| Overload in backup mode | Yes provided system will give indications at 101% load |
| Short Circuit in backup mode | System will shut down after 3-retries in case of output short circuit |
| Short Circuit in Mains Mode | Mains Fuse will blown |
| Back feed | System will shutdown in case of back feed and there is no retry |
| Over temperature | Yes provided\, if heat sink temperature goes above 100°C System will shut down |
| Reverse Battery | DC Fuse will blown |
| LED Status Display | Mains ON\, Input Voltage\, Input Frequency\, Battery Voltage\, Battery Charging\, Battery Charged\, Charging Current\, Backup Mode\, UPS ON\, UPS OFF\, Battery Voltage\, Load %\, Output Voltage\, Output Frequency\, Mains Low Cut\, Mains High Cut\, Mains Not Available\, Mains Frequency Cut |
| Buzzer | Audible beep for Overload\, Short Circuit\, Back feed\, Low Battery\, Over Temperature\, Mains Fuse blown / MCB Trip |